Online Offer Request Form 
   
Home Page About Us Quality Management PDF-Catalog Galery FAQ Services References Contact Us
Services
Restaurant
Fire Suppression Systems
FM 200 Gas
Fire Suppression Systems
CO2 Gas
Fire Suppression Systems
Novec -1230 Gas
Fire Suppression Systems
Inergen
Fire Suppression Systems
Sprinkler
Fire Suppression Systems
Foamy
Fire Suppression Systems
Dry Chemical
Fire Suppression Systems
Water Mist
Fire Suppression Systems
Argon Gas
Fire Suppression Systems
Micro
Fire Suppression Systems
FE 25
Fire Suppression Systems
Vehicle
Fire Suppression Systems
Fire Detection Systems
Fire Equipments
Maintenance
Automation Systems
 

Dealers Login
 User Name :
 Password :
Password Reminder 
tasarım uygulama mühendislik danışmanlık
CE    ISO    NFPA TSE-HYB    UL TSE   
 






Fire Equipments
Fire Pump

     Fire pumps are used to pressurized water and foam-water extinguishing systems. Horizontal split-bodied, end suction and vertical turbine type, including different types of UL listed, FM and LPCB approved or in accordance with NFPA 20 pumps and control panels are supplied by our company and imported. Pumps commissioning, maintenance, repair and testing provided by our company. Fire pump sets in general, 1 electric, 1 diesel to be selected as the main and redundant.

     In addition, jockey pump is used for the prevention and compensation small pressure losses in the system. Selecting the backup in case of electric power pomps feeds and feeding at least one from a reliable source of electrical power needed for seamless transfer of the "Auto Transfer Station" is required.

 

Fire Curtain

     A curtain system that produced from silicone-coated to the two sides and include the fiberglass steel ropes in, is used to prevent fire to pass from one region to another region. It keeps the temperature 1100 Celsius degree 180 minutes so this period provide us ease of movement and combat.

     Fire curtains can be integrated into existing fire detection systems, in danger they begin to work automatically.

Fire Cabinets

     The sale, installation and maintenance of the hydrants by KC Teknik and fire cabinets are assured from the domestic market, are imported if necessary.
Applications;

     Fire cabinets and hydrants are used with sprinkler and foam-sprinkler systems. Generally they are established in open areas. During the fire fire-fighting team and staff are provide pressurized water from them. Fire is generally confined to install cabinets. There are two different types of watery and sparkling.

Fire Gates and Fire Windows

     Fire doors are used to prevent of spread out the fires according to fire scenario, evacuation plans and architecture of the building or complexes, the rules of life safety; building escape stairways used as the gate, between the fire zones, to take part in fire walls, significant volumes of smoke and heat from the outside does not enter the critical risk with a warehouse or production areas, fog center, transformer offices, kitchens, spaces that may have a high fire load.

     Fire doors are used in schools, hospitals, shopping centers, industrial facilities, theater, cinema halls, such as impressions, such as the collection of fair meeting for the congress buildings, business centers and residences. Its resistance to fire, smoke and fire-proofing property, even when locked from the outside can open from inside with the panic bar system allows quick and safe evacuation situations.

Applications;

Fire doors  according to architecture, evacuation plans and fire senarious
Escape stairs of the building used as the gate discharge
Between fire zones
Fire in the walls
Warehouses at risk
Places with a high fire load, fire doors are used in order to spread the fire

Fire Stoppers

     Building fire stops are used in the cavities of the shaft through the cables in the cavity, for minimizing the blanks. Due to the sponge structure, is made by compressing the assembly.They are not pasted to the place so can be easily repaired.

     Each fire-stop product use the opening size, opening the material of the genus (the power cord, cable channel, EMT pipe, water pipe, air duct, etc..), the material of the amount (of openness in the% percentage rate), clearing the wall type (concrete, gypsum board, etc..), the vertical or horizontal openings, such as whether the factors to be used plays a major role in the selection of stops.

Exhaust and Ventilation Systems

Disposal of smoke;

     Entering the field of fire rescue personnel or fire department personnel will work out cooling a more relaxed during the process. At one point the fire smoke and heat is taken out before spreading to the other points so within the entire volume of products', systems', structural components' damage will be reduced. Heat accumulated in the course be increased to prevent the fire will be reduced and the acceleration in the volume of the products and systems to prevent the combustion temperature will be reached. Toxic gases, can not stay in there.
 

Emergency Lighting and Redirect Armatures

     Emergency lighting and redirect armatures, when normal lighting system are outages in case of (tamper, fire, network failure, etc.) with its self-powered battery groups, are enlighten the output paths and prevent the panic. With redirection armatures will help determine the best sexit point. Ensures fast and safe evacuatefrom in the structure.

     In case of fire, the building's electrical system will be the disabled, because of this it is an important role to light the place to reach the fire extinguisher and fire alarm buttons. They must be used in community public areas.

Fire Hydrants

     Regulation on the Protection of buildings from fire hydrant systems in the surrounding properties were determined by following items;

Article 95 - To protect buildings from fire, when the first interfere was not enough to fire fighting ,fire service will use hydrants from outside. Hydrants has to cover all around to the buildings. It is important to placed hydrants for fire officers and fire engines to reach quicker and on time to also make connections fire tools easily.

• Hydrant system design flow rate of at least 1900 l / min and flow rate should be increased according to risk class structure. Hydrant outlet pressure should be 700 kPa.
• Hydtants distance should be 50 m-too risky areas, 100 m-risky areas, 125 m-moderate risk areas,150 meters- low-risk areas.
• In normal conditions hydrants should be placed 5-15 m away from the building.
Which provides water to the hydrant system piping is not present in the ring system to be used should be minimum 150 mm diameter pipe.
• In the hydrant system, above ground fire hydrants should be used and must conform to the standard TS No. 2821.
• To renewal and maintain of the hydrant system, in the ground and / or above the ground lines' valves should be provided appropriate points and places.

Fire Walls

     Fire walls, industrial plants, warehouses, factories, and is used in areas with a high risk of fire. Implemented in order to prevent the growth of the fire nearer the event of fire. Production areas and storage areas of flammable, combustible products are used to distinguish between.

 


 
 
   
EXPERT YANGIN Fire Safety Systems

Kayışdağı Mah. Uslu Cad. Yunus Sokak
No: 8/A Ataşehir / İSTANBUL
Phone : 0 (216) 304 38 76 pbx   Fax : 0 (216) 304 38 76
E-Mail : info@expertyangin.com 
  Privacy
Yazılım & Tasarım :